    有什么可以幫您? 在線咨詢

    膠片沖洗工藝規程

    來源:濟寧儒佳檢測儀器有限公司   2012年08月15日 14:21  

    NJBST Co.,Ltd.
    QCD-017
    Rev.:0
    Page:1 of 3
    Title:   FILM PROCESSING PROCEDURE FOR RT RADIOGRAPHS  
     
     
     
       FILM PROCESSING PROCEDURE FOR RT RADIOGRAPHS  
     
     
     
     
    CONTROLLED   在控本
                           UNCONTROLLED 非在控本
                           COPY NO 副本編號:
     
     
     
     
     
     
    PREPARED BY 編制:         DATE 日期:
     
                  REVIEWED BY 審核:         DATE 日期:       
                 
                  APPROVED BY 批準:         DATE 日期:
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    NJBST Co.,Ltd.
    QCD-017
    Rev.:0
    Page:2 of 3
    Title:   FILM PROCESSING PROCEDURE FOR RT RADIOGRAPHS  
    1 Scope:
    1.1This procedure is compliance with the requirements of ASME Boiler and Pressure Vessel Code Section .
    1.2 This procedure establishes the process for controlling the film processing to produce a satisfactory radiograph.
    2 Qualification of Examination Personnel
     Any persons engaged in this examination shall be qualified as radiographic examiner in accordance with the Written Practice for the Training, Examination and Qualification of NDE Personnel.
    3 Automatic Processing
     Film characteristics must be compatible with processing conditions. It is essential that the recommendations of the film processor,  and chemical manufacturers be followed.
    4 Manual Processing
    4.1 Film and chemical manufacturers should be consulted for detailed recommendations on manual film processing.
    4.2 Preparation
       No more film should be processed than can be accommodated with a minimum separation of 20mm. Hangers are loaded and solutions stirred before starting development.
    4.3 Start of Development
       Start the timer and place the films into the developer tank. Sep a rate to a minimum distance of 20mm and agitate in two directions for about 15 s.
    4.4 Development
       Normal development is 5 to 8 min. at 68 °F( 20 ) . The manufacturer's recommendation should be followed in choosing a development time. Consult manufacturer recommended development time versus temperature charts. Other recommendations of the manufacturer to be followed are replenishment rates, renewal of solutions, and other specific instructions.
    4.5 Agitation
       Shake the film horizontally and vertically, ideally for a few seconds each minute during development. This will help film develop evenly.
    4.6 Stop Bath or Rinse
       After development is complete, the activity of developer remaining in the emulsion should be neutralized by an acid stop bath or, if this is not possible, by rinsing with vigorous agitation in clear water. Follow the film manufacturer's recommendation of stop bath composition(or length of alternative rinse), time immersed, and lift of bath.
    4.7 Fixing
     The films must not touch one another in the fixer. Agitate the hangers vertically for about 10 s and again at the end f the first minute, to ensure uniform and rapid fixation. Keep them in the fixer until fixation is complete (that is at least twice the clearing time), but not more than 15 min. In relatively fresh
    1 范圍
    1.1此規程根據ASME鍋爐和壓力容器規范第Ⅴ卷要求而制定。
    1.2 此規程建立一個控制膠片處理的“工藝”以獲得滿意的底片。
    2 人員資格
    任何從事射線探傷的人員必須按照《無損人員培訓、考試和資格認命的實施細則》進行資格考核評定。
    3 自動化處理
     根據膠片的特征選擇處理條件,必需采納自動洗片廠家的建議。
    4 手工處理
    4.1有關膠片的手工處理的具體實施應該遵照膠片及化學藥品制造廠商的建議。
    4.2準備
       將膠片裝到掛片夾上并在開始顯影之前攪動溶液。
    4.3開始顯影
       啟動計時器并將膠片浸入顯影液中,膠片間隔至少為1/2in 的距離,并不斷將顯影夾上下移動大約15S。
    4.4顯影
       正常顯影在68°F(20℃)時為5~8分鐘,在選擇顯影時間時應遵循生產廠的推薦,此外,應參考制造廠推薦的顯影時間和溫度關系表,其它應遵循制造廠推薦的內容為補液率、溶液的更換,以及其它特殊的說明。
     4.5攪動
       在顯影過程中,一分鐘內將膠片作水平和垂直方向攪動數秒鐘,這有助于膠片均勻顯影。
    4.6停顯或漂洗
     在顯影結束后,應用酸性停顯液來中和顯影劑的活性,如果不能用停顯液,則可通過有清水中將膠片強有力拌動來進行漂洗,停顯液的成份(或漂洗時間)膠片的浸漬時間以及停顯液的的使用期限等,均應遵照膠片生產廠的推薦。
    4.7定影
     膠片在定影液中不得互相接觸,為保證均勻而快速的定影,膠片在剛浸定影液時,以及在*分鐘末,均應做上下方向的攪動,約10秒鐘,以確保均勻迅速的定影,然后讓其在定影液中浸漬到定影結(其時間至少為達到底片透明所需時間的兩倍)但在
    NJBST Co.,Ltd.
    QCD-017
    Rev.:0
    Page:3 of 3
    Title:   FILM PROCESSING PROCEDURE FOR RT RADIOGRAPHS  
     fixer. Frequent agitation will shorten the time of fixation.
    4.8 Fixer Neutralizing
       The use of a HUPO eliminator or fixer neutralizer between   fixation and washing may be advantageous. The recommendations of the manufacturers as to preparation, use, and useful lift of the baths should be observed rigorously.
    4.9 Washing
       Washing is very slow below 60 °F ( 16 ) . When washing at temperatures above 85°F (30), care should be exercised not to leave films in the water too long. The films should be washed in batches without contamination from new film brought over from the fixer.
    4.9.1 The cascade method of washing uses less water and gives better washing for the same length of time. Divide the wash tank into two sections (may be two tanks). Put the films from the fixer in the outlet section. After partial washing, move the batch of film to the inlet section. This comletes the wash in fresh water.
    4.9.2 For specific washing recommendations, consult the film   manufacturer.
    4.10 Wetting Agent
        Dip the film for approximay 30 s in a wetting agent. This markers water drain evenly off film which facilitates quick, even drying.
    4.11 Residual Fixer Concentrations
        If the fixing chemicals are not removed adequay from the film, they will in time cause staining or fading of the developed image. Residual fixer concentations permissible depend upon whether the films are to be kept for commercial purposes (3 to 10 years) or must be of archival quality. The method of determining residual fixer concentrations may be ascertained by reference to ANSI PH4.8, PH1.28, and PH1.41.
    4.12 Drying
       Manual drying can vary from still air drying at ambient temperature to as high as 140°F (60) with air circulated by a fan. Film manufacturers should again be contacted for recommended drying conditions. Take precaution to tighten film on hangers, so that it cannot touch in the dryer. Too hot a drying temperature at low humidity can result in unever drying and should be avoided.
    較新鮮的定影液中,不得超過15分鐘,經常攪動膠片可以縮短定影時間。
    4.8定影液的中和
       在定影和沖水之間,使用海波凈化劑或定影液中和劑可能會有好處,對制造廠推薦的試劑配制,使用以及使用期限等應嚴加注意。
    4.9水洗
     一般在60°F(16℃)以下時沖洗是很緩慢的,在溫度85°F(30℃)以上沖洗時,應當注意膠片在水中時間不能太長,膠片應分批沖洗,不能有新從定影液中取出的膠片,以免污染。
    4.9.1 分級沖洗法所需的水量較少,并在同樣的沖洗時間里能達到較好的沖洗效果。把沖洗槽分為兩個部分(也可用兩個水槽),把從定影液中取出的膠片放在出水口部分,經過部分沖洗后,把膠片移到進水口部分,從而在新鮮水中完成沖洗。
    4.9.2 有關特殊的沖洗推薦方法應征詢膠片制造廠。
    4.9.3 水洗的有效性可以用ANSTPH4.8操作方法E94中所述的處理殘留化學物質試驗來檢查。
    4.10潤濕劑
        把膠片浸入潤濕劑中約30秒鐘,可以使水從膠片上均勻流下,易于干燥得快速、均勻。
    4.12 干燥
        手工干燥可以從環境溫度的靜止空氣直到高達140°F(60的鼓風機循環空氣下進行干燥,對膠片的干燥條件也應參照膠片制造廠推薦,要注意在掛夾上繃緊膠片,防止在干燥器中接觸,低濕度下過高的干燥溫度會引起不均勻的干燥,是應當避免的。
     

    免責聲明

    • 凡本網注明“來源:儀表網”的所有作品,均為浙江興旺寶明通網絡有限公司-儀表網合法擁有版權或有權使用的作品,未經本網授權不得轉載、摘編或利用其它方式使用上述作品。已經本網授權使用作品的,應在授權范圍內使用,并注明“來源:儀表網”。違反上述聲明者,本網將追究其相關法律責任。
    • 本網轉載并注明自其它來源(非儀表網)的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點或和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品第一來源,并自負版權等法律責任。
    • 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。
    聯系我們

    客服熱線: 15024464426

    加盟熱線: 15024464426

    媒體合作: 0571-87759945

    投訴熱線: 0571-87759942

    關注我們
    • 下載儀表站APP

    • Ybzhan手機版

    • Ybzhan公眾號

    • Ybzhan小程序

    企業未開通此功能
    詳詢客服 : 0571-87759942
    主站蜘蛛池模板: 欧美国产成人精品一区二区三区| 国产成人AV免费观看| 成人毛片一区二区| 国产成人无码AV一区二区 | 美国成人免费视频| 青青国产成人久久91网站站| 国产成人亚洲午夜电影| 国产成人国产在线观看入口| 国产成人欧美一区二区三区| 国产婷婷成人久久av免费高清| 亚洲国产精品成人久久久| 欧美成人看片黄a免费看| 欧美成人xxx| 亚洲国产精品成人久久久 | 亚洲精品成人区在线观看| 18成人片黄网站www| 国产精品成人va在线观看 | 欧美激情成人网| 国内外成人在线视频| 亚洲国产成人久久一区www| 欧美成人免费一区二区| 久久国产成人精品| 日韩精品无码成人专区| 亚洲人成人77777网站不卡| 成人欧美一区二区三区视频| 亚洲国产成人精品青青草原| 国产精成人品日日拍夜夜免费| 久久久久成人片免费观看蜜芽| 亚洲欧美日韩国产成人| 久久久久亚洲AV成人片| 亚洲欧美成人中文日韩电影| 亚洲国产精品成人久久| 国产亚洲精品成人久久网站| 成人A级视频在线播放| 国产成人天天5g影院| 亚洲欧洲精品成人久久曰| 精品成人一区二区三区免费视频| 1000部国产成人免费视频| 国产成人免费一区二区三区| 国产成人精品福利色多多| 中文国产成人精品久久水|