• <del id="qqie6"><sup id="qqie6"></sup></del>
  • <tfoot id="qqie6"></tfoot>
  • <ul id="qqie6"></ul>
  • 青島科迪博電子科技有限公司
    免費會員

    當前位置:青島科迪博電子科技有限公司>>妙測 M&C>> 取樣探頭

    取樣探頭

    參  考  價面議
    具體成交價以合同協議為準

    產品型號

    品       牌

    廠商性質經銷商

    所  在  地青島市

    聯系方式:張先生查看聯系方式

    更新時間:2023-06-26 07:34:58瀏覽次數:147次

    聯系我時,請告知來自 儀表網
    同類優質產品更多>
    SP2000-H/DILBasedonprobeSP2000H/

    SP2000-H/DIL

    Based on probe SP2000H/....

    Electrically heated up to 180°C

    External critical orifice is heated

    Including a dilution gas pre-heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


    SP2300-H/DIL

    Based on probe SP2300H/....

    Electrically heated up to 180°C

    External critical orifice is heated

    Including a dilution gas pre-heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    Material: PTFE, FPM, ceramic

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2300H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


    SP2000-H320/DIL

    Based on probe SP2000H/....

    Electrically heated up to 320°C

    External critical orifice is heated

    Including a dilution gas pre-heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


    SP2000-H/DIL-VA

    Based on probe SP2000H/....

    Electrically heated up to 180°C

    External critical orifice is heated

    Including a dilution gas pre- heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    With integrated ball valve at the probe inlet

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas.


    SP2000-H/DIL-B

    Based on probe SP2000H/....

    Electrically heated up to 180°C

    External critical orifice is heated

    Including a dilution gas pre- heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    With bypass injector to minimize the response time

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


    SP2000-H320/DIL-B

    Based on probe SP2000H/....

    Electrically heated up to 320°C

    External critical orifice is heated

    Including a dilution gas pre- heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    With bypass injector to minimize the response time

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


    SP2000-H/DIL-BR

    Based on probe SP2000H/....

    Electrically heated up to 180°C

    External critical orifice is heated

    Including a dilution gas pre- heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    With bypass injector to minimize the response time and integrated gas recirculation

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

    SP2000-H320/DIL-BR

    Based on probe SP2000H/....

    Electrically heated up to 320°C

    External critical orifice is heated

    Including a dilution gas pre- heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    With bypass injector to minimize the response time and integrated gas recirculation

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

    SP2000-H/DIL-VA-B

    Based on probe SP2000H/....

    Electrically heated up to 180°C

    External critical orifice is heated

    Including a dilution gas pre- heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    With integrated ball valve at the probe inlet and bypass injector to minimize the response time

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector minimizes the response time.


    SP2000-H/DIL-VA-BV

    Based on probe SP2000H/....

    Electrically heated up to 180°C

    External critical orifice is heated

    Including a dilution gas pre-heater

    No dew point problems

    Dilution rates from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Easy operation and maintenance

    With heated hand-operated ball valve at the sample inlet and bypass connection with needle valve in order to minimize the response time

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector with needle valve minimizes the response time.


    SP2006-H/DIL-B/2x/F

    Based on probe SP2000-H/...

    Electrically heated up to 180 °C or 280 °C

    NEMA 4, FRP housing

    External heated critical orifice with additional safety filter

    Including a dilution gas pre-heater

    No dew point problems

    Dilution ratios from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Changing of dilution and bypass block without any tools within a few minutes

    No disconnection of any tubes or hoses for changing of dilution or bypass block

    Easy operation and maintenance

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


    SP2006-H/DIL-BR/2x/F

    Based on probe SP2000-H/...

    Electrically heated up to 180 °C or 280 °C

    NEMA 4, FRP housing

    External heated critical orifice with additional safety filter

    Including a dilution gas pre-heater

    No dew point problems

    Dilution ratios from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Changing of dilution and bypass block without any tools within a few minutes

    No disconnection of any tubes or hoses for changing of dilution or bypass block

    Easy operation and maintenance

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


    SP2006-H/DIL/2x/F

    Based on probe SP2000-H/...

    Electrically heated up to 180 °C or 280 °C

    NEMA 4, FRP housing

    External heated critical orifice with additional safety filter

    Including a dilution gas pre-heater

    No dew point problems

    Dilution ratios from 10:1 up to 500:1

    With check gas connection

    Independent of the process temperature

    Changing of dilution and bypass block without any tools within a few minutes

    No disconnection of any tubes or hoses for changing of dilution or bypass block

    Easy operation and maintenance

    Application:

    The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.

    會員登錄

    ×

    請輸入賬號

    請輸入密碼

    =

    請輸驗證碼

    收藏該商鋪

    X
    該信息已收藏!
    標簽:
    保存成功

    (空格分隔,最多3個,單個標簽最多10個字符)

    常用:

    提示

    X
    您的留言已提交成功!我們將在第一時間回復您~
    在線留言
    主站蜘蛛池模板: 久久久久亚洲AV成人无码电影| 国产成人亚洲精品| 国产成人精品自线拍| 国产成人精品午夜视频'| 国产成人免费A在线视频| 久久久久99精品成人片试看| 欧美成人高清ww| 国产成人无码AⅤ片在线观看| 久久天堂成人影院| 在线观看国产精成人品| 久久青青成人亚洲精品| 成人国产永久福利看片| 国产成人在线观看网站| 成人短视频完整版在线播放| 国产成人精品97| 91久久亚洲国产成人精品性色| 日本成人在线播放| 亚洲国产成人久久三区| 成人五级毛片免费播放| www成人免费观看网站| 国产成人免费av片在线观看| 成人永久福利在线观看不卡| 99久久国产综合精品成人影院| 国产成人精品视频福利app| 欧美成人中文字幕dvd| 亚洲国产成人久久一区www| 国产成人亚洲综合在线| 国产成人精品久久一区二区小说| 欧美成人在线影院| 久久成人无码国产免费播放| 国产成人午夜高潮毛片| 国产日产成人免费视频在线观看| 成人永久免费福利视频app| 欧美成人看片黄a免费看| 久久久久亚洲AV成人网人人网站| 亚洲成人动漫在线观看| 国产成人亚洲精品无码AV大片| 在线观看成人网站| 国产成人无码av在线播放不卡| 国产精品成人免费视频网站| 国产成人va亚洲电影|